Building Type:
Location:
New/Existing:
Research Category :
Research Sponsor:
California Energy Commission (CEC)
AEA's Role:
Implementer of field study
Indoor Air Quality in New and Renovated Low-Income Apartments with Mechanical Ventilation and Natural Gas Cooking in California
Research Team:
Lawrence Berkeley National Laboratory, AEA
Challenge:
Previous research completed by the Lawrence Berkeley National Laboratory has shown cooking to be a major contributor to indoor air pollutants in the home. While electric burners do produce some pollutants (ultrafine particles and some NOx), natural gas burners have been shown to be major contributors of these pollutants in addition to CO, CO2, formaldehyde, VOCs, and PM2.5 particles, all of which could have health implications. Sufficient ventilation could make the production of these substances a non-issue, however additional research has shown that typical kitchen hoods do not collect 100% of cooking byproducts, and are frequently misused or left unused. This concern is exacerbated in apartments, where the internal volume is smaller than a typical single family home, resulting in more rapid pollutant buildup. Title 24 standards have been updated to require continual ventilation, but it is unclear currently if this in addition to a typical range hood is sufficient to remove these contaminants from the air.
Project Objective:
In this study, AEA installed equipment to monitor air quality and kitchen usage in 23 low-income apartments at four properties across California climate zones, all of which had been renovated or newly constructed between 2013-2017, and so met the 2013 Title 24 code. This monitoring equipment in addition to occupant-entered logs and surveys, allowed the researchers to evaluate air quality in the apartments over a 1-2 week period and tie specific air quality events with occupant actions. Air quality impacts as a result of gas-fired cooktops were compared with ventilation rates and evaluated for potential health impacts.
Challenge
Previous research completed by the Lawrence Berkeley National Laboratory has shown cooking to be a major contributor to indoor air pollutants in the home. While electric burners do produce some pollutants (ultrafine particles and some NOx), natural gas burners have been shown to be major contributors of these pollutants in addition to CO, CO2, formaldehyde, VOCs, and PM2.5 particles, all of which could have health implications. Sufficient ventilation could make the production of these substances a non-issue, however additional research has shown that typical kitchen hoods do not collect 100% of cooking byproducts, and are frequently misused or left unused. This concern is exacerbated in apartments, where the internal volume is smaller than a typical single family home, resulting in more rapid pollutant buildup. Title 24 standards have been updated to require continual ventilation, but it is unclear currently if this in addition to a typical range hood is sufficient to remove these contaminants from the air.
Project Objective
In this study, AEA installed equipment to monitor air quality and kitchen usage in 23 low-income apartments at four properties across California climate zones, all of which had been renovated or newly constructed between 2013-2017, and so met the 2013 Title 24 code. This monitoring equipment in addition to occupant-entered logs and surveys, allowed the researchers to evaluate air quality in the apartments over a 1-2 week period and tie specific air quality events with occupant actions. Air quality impacts as a result of gas-fired cooktops were compared with ventilation rates and evaluated for potential health impacts.
Building Type:
Location:
New/Existing:
Research Category :
Research Sponsor:
California Energy Commission (CEC)
AEA's Role:
Implementer of field study